Volts DC). If the MIN
Trimpot is set to other
than 0 Volts DC, the
motor will run at that
speed when the
switch or contact is
opened. An open col-
lector (PNP) can be
wired in lieu of a
switch or contact.
Note: The decelera-
tion time can only be
made longer than the
normal coasting time
of the load.
6.8 Inhibit Circuit Connection – The control can be stopped
and started with an Inhibit circuit (close to stop, open to run).
Wire the switch or contact to Terminals “I1” and “I2”, as
shown in Figure 7. When the switch or contact is closed, the
motor will coast to stop. When the switch or contact is
opened, the motor will accelerate to the Main Speed
Potentiometer setting. An open collector (NPN) can be wired
in lieu of a switch or contact.
WARNING! The Inhibit Circuit is never to be used
as a Safety Disconnect since it is not fail-safe. Use
only the AC line for this purpose.