Kb-electronics KBDA-42 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software Kb-electronics KBDA-42 herunter. KB Electronics KBDA-42 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 57
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
MODELS KBDA-24P & KBDA-42 SUPPLEMENT
IMPORTANT: The KBDA Series manual must be read and understood before attempting
to operate the drive. For further assistance, contact our sales Department at
954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Models KBDA-24P and KBDA-42 have been added to the KBDA Series
of drives. These models are designed to accept 3-phase AC line input only. Table 3A
shows the Electrical Ratings. Figure 11A shows the AC Line input, Motor, and Ground
connections to Terminal Block TB1. The General Performance Specifications have not
changed (see the manual for specifications). Both models contain AC Line Phase Loss
Detection.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 3A
ELECTRICAL RATINGS
AC Line Input Output
Model
Part No.
(Gray / White
1
)
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
KBDA-24P 9766 / 9767 208/230 3 4.7 10 0 – 208/230 3.6 1 (0.75)
KBDA-42
2
9763 / 9764 400/460 3 2.6 5 0 – 400/460 2.0 1 (0.75)
Notes: 1. White FDA approved finish. 2. Model KBDA-42 is rated 0 – 400 Volts AC for 50
Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
FIGURE 11A
AC LINE INPUT, MOTOR, AND GROUND CONNECTIONS
KB Electronics, Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 (954) 346-4900 FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 info@kbelectronics.com
www.kbelectronics.com (A42040) – Rev. A00 – 6/9/2009
MODELS KBDA-24P & KBDA-42 SUPPLEMENT
IMPORTANT: The KBDA Series manual must be read and understood before attempting
to operate the drive. For further assistance, contact our sales Department at
954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Models KBDA-24P and KBDA-42 have been added to the KBDA Series
of drives. These models are designed to accept 3-phase AC line input only. Table 3A
shows the Electrical Ratings. Figure 11A shows the AC Line input, Motor, and Ground
connections to Terminal Block TB1. The General Performance Specifications have not
changed (see the manual for specifications). Both models contain AC Line Phase Loss
Detection.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 3A
ELECTRICAL RATINGS
AC Line Input Output
Model
Part No.
(Gray / White
1
)
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
KBDA-24P 9766 / 9767 208/230 3 4.7 10 0 – 208/230 3.6 1 (0.75)
KBDA-42
2
9763 / 9764 400/460 3 2.6 5 0 – 400/460 2.0 1 (0.75)
Notes: 1. White FDA approved finish. 2. Model KBDA-42 is rated 0 – 400 Volts AC for 50
Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
FIGURE 11A
AC LINE INPUT, MOTOR, AND GROUND CONNECTIONS
KB Electronics, Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 (954) 346-4900 FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 info@kbelectronics.com
www.kbelectronics.com (A42040) – Rev. A00 – 6/9/2009
Seitenansicht 0
1 2 3 4 5 6 ... 56 57

Inhaltsverzeichnis

Seite 1

MODELS KBDA-24P & KBDA-42 SUPPLEMENT IMPORTANT: The KBDA Series manual must be read and understood before attempting to operate the drive. For f

Seite 2 - KBDA SERIES

9DescriptionAccessory Part No.ModelKBDA-24DModelKBDA-27DModelKBDA-29ModelKBDA-45ModelKBDA-48On/Off AC Line Switch – Disconnects the AC line. Mounts on

Seite 3

10Notes: 1. White FDA approved finish. 2. Bold indicates factory setting of AC line input voltage for Models KBDA-24D, 27D. 3. Factory settingof motor

Seite 4 - UL Notice

TB1WU V L2L1L1A L2BL2AL1BTB2NO COMNCCON1MOTOR AC LINE115VJ1230V11FIGURE 3 – MODEL KBDA-24D DRIVE LAYOUT

Seite 5

J1115V 230VMOTORW L2 L3U VTB1AC LINETB2NO COMNCCON1L2A L1AL2B L1B12FIGURE 4 – MODEL KBDA-27D DRIVE LAYOUT

Seite 6

AC LINEL2A L3AL1AL3BL2BL1BL1W L2 L3U VTB1MOTORTB2NCCOMNOCON113FIGURE 5 – MODELS KBDA-29, 45, 48 DRIVE LAYOUT

Seite 7

5.86149Max. Depth:2088.209.532428.852250.317.975.511405.061292Xø7.02.530.27564.43*2*4*4* 1*1*14Model KBDA-24D contains mounting holes for standard 1/2

Seite 8

0.2754Xø7.00.307.372X25.41.002X7.25Max. Depth:1848.502169.252359.802493*1817.551927.152*4* 1*15Models KBDA-27D, 29, 45, 48 contain two mounting holes

Seite 9

4 IMPORTANT APPLICATION INFORMATION4.1 MOTOR WITH EXTERNAL FAN COOLING – Most totally enclosed fan-cooled (TEFC) and openventilated 3-phase AC inducti

Seite 10

If the motor is overloaded to 120% of the Motor Nameplate Rated Current setting, the I2tTimer starts. If the motor continues to be overloaded at the 1

Seite 11 - TABLE 3 – ELECTRICAL RATINGS

6.1 AC LINE INPUT CONNECTION (see Warning, on page 17) – Connect the AC line input toTerminal Block TB1. See Electrical Ratings, Table 3, on page 10.A

Seite 12 - MOTOR AC LINE

Installation & Operation ManualKBDA SERIES• Simplified Group Programming • 8 LED Status IndicatorsMULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY

Seite 13 - W L2 L3U V

6.2 GROUND CONNECTION – Connect the ground wire (earth) to any available green Ground Screw.The two Ground Screws are located near Terminal Block TB1.

Seite 14 - L1W L2 L3U V

8 RECOMMENDED HIGH VOLTAGE DIELECTRIC WITHSTAND TESTING (HI-POT TESTING)Testing agencies such as UL, CSA, VDE, etc., usually require that equipment un

Seite 15 - 4*4* 1*1*

9 DRIVE OPERATIONBefore operating the drive, read Section 9.2, for instructions on the Digital Keypad Operation. SeeFigure 2, on page 10, for the keyp

Seite 16

9.3 FLOW CHARTS FOR IMPORTANT PROGRAMMING FUNCTIONS – See Figures 16 – 22, onpages 23 – 29, for flow charts to program important functions. The flow c

Seite 17 - Fan or Blower

23FIGURE 16 – FLOW CHART TO PROGRAM THE DRIVE FOR 50 HZ MOTORSSet Frequency Flashes("FWD", "STOP", "Hz" LEDs On)("P

Seite 18

24FIGURE 17 – FLOW CHART TO PROGRAM MOTOR CURRENT FROM 6.7 AMPS TO 5.5 AMPS*For Models KBDA-27D, 29, the factory setting of Motor Nameplate Current (F

Seite 19 - 2 HP maximum

25FIGURE 18 – FLOW CHART TO CHANGE SET FREQUENCY FROM 5.00 Hz TO 43.21 Hz(DRIVE IN THE STOP MODE)**If Function No. 2.01 is set to “0000”, frequency ch

Seite 20

26FIGURE 19 – FLOW CHART TO PROGRAM ACCEL TIME FROM 1.5 SECONDS TO 120 SECONDS("FWD", "STOP", "Hz" LEDs On)Set Frequency

Seite 21 - VOLTAGE SELECTION

27*The factory setting of Display Mode (Function No. 4.00) is Frequency (“0000”).FIGURE 20 – FLOW CHART TO PROGRAM THE DRIVE TO DISPLAY MOTOR RPM Digi

Seite 22 - AC KILOVOLTS

28FIGURE 21 – FLOW CHART TO PROGRAM THE DRIVE TO DISPLAY CUSTOM UNITS “012.0”Set Frequency Flashes("FWD", "STOP", "Hz" L

Seite 23 - TABLE 6 – KEYPAD DESCRIPTION

TABLE OF CONTENTSSection Page1 Quick-Start Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 24 - Z MOTORS

29*Function Nos. 4.04 – 4.06 set to “0001”.FIGURE 22 – FLOW CHART SHOWING MOTOR CURRENT, MOTOR VOLTAGE, AND BUS VOLTAGEADDED TO THE BASIC DISPLAY*(&qu

Seite 25

30TABLE 7 – DIGITAL READOUT CODES*Model KBDA-29: when used on 3-phase AC line input set for 7.0 Amps or higher (3 HP (2.25 kW)).Display DescriptionDri

Seite 26 - (DRIVE IN THE STOP MODE)*

319.5 FAULT RECOVERY – The drive monitors many faults. See Function No. 1.05, on page 33, forrestarting the drive after a fault has been cleared. See

Seite 27

32Note: (1) IODA Option Board required. (2) DIAC Option Board required.KBDA PROGRAMMABLE FUNCTION SUMMARY LIST (REV. 100.1)FunctionGroup No. Descripti

Seite 28

33FunctionNo. Description Range/CodeFactorySetting1.00* Run/Stop-Forward/Reverse Control0000: Keypad0001: External Contacts(1)0002: Communication(2)00

Seite 29

34FunctionNo. Description Range/CodeFactorySetting3.00 Stored Set Frequency (Hz) 0.00 – 240.0 5.003.01 Lower Frequency Limit (Hz) 0.00 – 240.0 0.003.0

Seite 30 - ADDED TO THE BASIC DISPLAY*

35FunctionNo. Description Range/CodeFactorySetting4.00 Display Mode0000: Frequency0001: RPM(1)0002: Custom Units00004.01 Custom Units Significant Digi

Seite 31

36FunctionNo. Description CodeFactorySetting6.00* Software Version — —6.01* Drive Horsepower — —6.02* Fault Log 1 — —6.03* Fault Log 2 — —6.04* Fault

Seite 32

37FunctionNo. Description Range/CodeFactorySetting8.00*Multi-Function Output Relay 1(Terms.23 – 25)0000: Run0001: Fault(1)0002: Target Frequency(Funct

Seite 33 - PROGRAMMABLE FUNCTION GROUPS

38FUNCTION GROUP 9 – ANALOG INPUT SIGNAL OPERATION(IODA OPTION BOARD REQUIRED)Notes: (1) For Analog Input 1 (Function Nos. 9.00 – 9.04), Frequency Con

Seite 34

20 Flow Chart to Program the Drive to Display Motor RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 21 Flow Chart to

Seite 35

39FUNCTION GROUP 10 – COMMUNICATION MODE(DIAC OPTION BOARD REQUIRED) (Continued)** Read only.FunctionNo. Description Range/CodeFactorySetting10.04 Dri

Seite 36

40FunctionNo. Description Range/CodeFactorySetting11.00 – 11.09 Reserved — —FUNCTION GROUP 11 – RESERVED FUNCTIONSModel No. Software Revision CodeKBDA

Seite 37 - (IODA OPTION BOARD REQUIRED)

4111 DIAGNOSTIC LEDsThe drive contains 8 Status LEDs to provide indication of the drive’s status and operating mode (Hz,PGM, LCL/REM, STOP, FWD, REV,

Seite 38

42APPENDIX A – OPTIONAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARDThe IODA Input/Output Multi-Function Board provides a variety of functions, which includ

Seite 39

43FIGURE 24 – IODA LAYOUT (ALL MODELS)*CON1CON2:FactoryUse OnlyIODATwo Snap-Ins to Secure IODA to Mounting BaseJ2 & J3: Current or Voltage Signal

Seite 40

44TABLE 12 – IODA FUNCTIONS AND FEATURESMulti-FunctionInput Terminal CodesTerminal AssignmentMulti-FunctionInputTerminals1(Digital Inputs)PowerSupply2

Seite 41

45A2. UP/DOWN FREQUENCY COMMANDThe Multi-Function Input Terminals can be used for remote Up/Down Frequency control in lieu of theKeypad or the Built-I

Seite 42 - TABLE 9 – LED DESCRIPTIONS

46A4. FORWARD/STOP AND REVERSE/STOP COMMANDThe Multi-Function Input Terminals can be used for remote Forward/Stop and Reverse/Stop operationby connect

Seite 43

47A6. RESETThe Multi-Function Input Terminals can be used to reset the drive, after a fault has been cleared, byconnecting a switch or contact to any

Seite 44

48FIGURE 32 – 2-WIRE START/STOP SWITCH OR CONTACT CONNECTION AND FUNCTION SETTINGS4Start/Stop2115 16317 18TB16519208721 2210923 24121125 2614132827(Cl

Seite 45

IMPORTANT APPLICATION INFORMATION1. 50 Hz Motors – This drive has been factory programmed to operate 60 Hz motors. For 50 Hz motoroperation, set Funct

Seite 46

49A8. SIGNAL FOLLOWINGAn analog voltage (unidirectional or bidirectional), current, or PWM signal input can be used to controlmotor speed in lieu of t

Seite 47 - Accel/Decel 2

50TABLE 14 – ANALOG INPUT 1 ELECTRICAL RATINGSFIGURE 35 – ANALOG INPUT 2 SIGNAL CURRENT FOLLOWING CONNECTION AND FUNCTION SETTINGS14432116TB115 17 181

Seite 48 - Forward/Stop

51A10. REMOTE MAIN SPEED POTENTIOMETERA remote Main Speed Potentiometer (5 kΩ) can be used in lieu of the Keypad or the Built-InPotentiometer. The Mai

Seite 49 - Start/Stop

52FORWARD MOTOR OPERATIONAnalog Input 1 – Connect the potentiometer to Terminals “9” (+5 Volts), “19” (Analog Input 1), and“20” (Common). Set Frequenc

Seite 50 - 0 - ±5 Volts DC V

53A12. MULTI-FUNCTION OPEN COLLECTOR OUTPUTSTwo Open Collector Outputs are provided, which can be programmed for Run, Fault, TargetFrequency, Frequenc

Seite 51 - 0 - 20 mA DC

54FIGURE 39 – MULTI-FUNCTION OPEN COLLECTOR CONNECTIONS AND FUNCTION SETTINGSTB1COMOutput 214416151 217 183 921519206227 823Output 126O.C.10242511O.C.

Seite 53 - Main Speed

LIMITED WARRANTYFor a period of 18 months from the date of original purchase, KB Electronics, Inc. will repair or replacewithout charge, devices which

Seite 54

1.1 AC LINE INPUT CONNECTION – Connect the AC line input to Terminal Block TB1. See Section6.1, on page 18.Application Note – If operation with a Grou

Seite 55

2 SAFETY WARNINGDefinition of Safety Warning SymbolsElectrical Hazard Warning Symbol – Failure to observe this warning could result in electricalshock

Seite 56 - – NOTES –

3 INTRODUCTIONThank you for purchasing the KBDA Adjustable Frequency Drive. KB Electronics, Inc. is committed toproviding total customer satisfaction

Seite 57 - LIMITED WARRANTY

• LED Status Indicators – The LEDs provide indication of the drive’s status and operating mode(Hz, PGM, LCL/REM, STOP, FWD, REV, OL, JOG/REM).• Multi-

Verwandte Modelle: KBDA-24P

Kommentare zu diesen Handbüchern

Keine Kommentare