CON2: Used for optional Forward-Stop-Reverse Switch.*
* The optional Forward-Stop-Reverse Switch is required for Manual Start.
Main Speed Potentiometer Terminals (P1, P2, P3).
Adjustable Trimpots (CL, MAX, MIN, ACCEL, DECEL, COMP).
J4: 1X or up to 2X Rated Motor RPM Operation.
J6: "Run" or "Fault" Output Relay.
J3: Automatic or Manual Start and Reset Operation.*
TB1: AC Line Input, Motor, Ground, and connections. See Figure 7, on page 15.
J5: 60 Hz or 50 Hz Motor Operation.
TB2: Run/Fault Relay Output Contacts.
J2: Motor Horsepower.
Jumpers and trimpots are shown in factory set positions.
CON1: Used to connect optional accessories to the drive.
Install jumper for 115 Volt AC line input. See Figure 9, on page 16.
J1: AC Line Input Voltage selection.
Diagnostic LEDs (Power On, Status, Overload).
Main Speed Potentiometer
(Front View)
Panel Mounted
Violet
Orange
White
Pilot Lamp
Panel Mounted
On/Off AC Line Switch
(Back View)
Panel Mounted
Black
Blue
Blue
Black
White
White
L1B L1A L2A L2B
CON1
115VAC
J1
J1-A
A
B
J1-B
U GNDV W L1 L2
TB1
MOTOR
AC LINE
N.O.COMN.C.
TB2
OL
ON
ST
F
R
S
CON2
P
1
P
2
P
3
J6
FLT
RUN
FREQ
50HZ
60HZ
J5
J3
J2
1/2
1/8
1/4
3/4
1HP
MULT
AUTO
1X
J4
2X
MAN
ACCEL
C
M
P
E
C
C
O
D
COMP DECEL
N
C
A
I
M
M
X
A
C
L
MIN MAX CL