Kb-electronics KBVF-23P Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 45
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
Current Limit (CL) Sets the current limit (overload) which limits the maximum current
(torque) to the motor. See Section 13.7, on page 42.
3.5 Optional Accessories
SIVFR — Signal Isolator and Run/Fault Relay (Part No. 9597) – Provides isolation
between a non-isolated signal voltage (0 to ±2.5 thru 0 to ±25 Volts DC) or current source
(4 – 20 mA DC) and the drive. Can be used in single-ended or bidirectional mode. Run/Fault
Relay Output Contacts are also provided, which can be used to turn on or off equipment or
to signal a warning if the drive is put into the Stop Mode or a fault has occurred. Mounts on
the end of the drive’s heat sink.
DBVF — Dynamic Brake Module (Part No. 9598) Provides up to 25% continuous
braking and 200% instantaneous braking torque (maximum 1 HP (0.75 kW)).
Multi-Speed Board (Part No. 9503) – Provides multi-speed operation using external
contacts or a PLC. Mounts on the end of the drive’s heat sink.
Programming Kit (Part No. 9582) – Includes DownLoad Module™ (DLM) handheld
programming device which uploads and downloads drive programs, PC to DLM serial com-
munication cable, DLM to inverter communication cable, and PC Windows® based Drive-
Link™ communication software. Contact our Sales Department for more information.
DIVF — Modbus Communication Module (Part No. 9568) Allows the drive to communi-
cate with PLCs, PCs, and HMIs with Modbus* RTU protocol utilizing a serial communication
cable. If a USB communication cable is required, purchase Part No. 19008.
*Other Protocols available. Contact our Sales Department.
RFI Filters and Chokes Provide RFI and EMI Suppression. They comply with CE Council
Directive 89/336/EEC relating to the Class A Industrial and Class B Residential Standards.
See RFI Filters and Chokes Selection Guide Publication No. D-321 (Part No. A42027).
Custom Software – All models can be factory programmed for applications that require spe-
cial switching, timing, PLC functions, and GFCI operation. Contact our Sales Department.