14
TABLE 1 – ELECTRICAL RATINGS
Model
Part
No.
AC Line Input
Fuse or
Circuit Breaker
Rating
(Amps)
Drive Output
Net Wt.
Volts AC
(50/60 Hz)
Phase
(φ)
Maximum
Current
(Amps AC)
Voltage
Range
(Nominal)
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW)) lbs kg
KBVF-21D 9581
115 1 4.0
5 0 – 230 1.0 1/10 (.07) 0.7 0.3
208/230 1 2.5
KBVF-22D 9572
115 1 6.0 10
0 – 230 1.5 1/4 (.18) 1.3 0.6
208/230 1 3.8 5
KBVF-13 9957 115 1 9.6 15 0 – 230 2.4 1/2 (.37) 1.3 0.6
KBVF-23 9958 208/230 1 6.0 10 0 – 230 2.4 1/2 (.37) 1.3 0.6
KBVF-23D 9959
115 1 9.6 15
0 – 230 2.4 1/2 (.37) 1.3 0.6
208/230 1 6.0 10
KBVF-23P 9676 208/230 3 3.2 5 0 – 230 2.4 1/2 (.37) 1.1 0.5
KBVF-14 9977 115 1 14.0 20 0 – 230 4.0 1 (.75) 2.2 1.0
KBVF-24 9978 208/230 1 10.0 15 0 – 230 4.0 1 (.75) 2.2 1.0
KBVF-24D 9979
115 1 14.0 20
0 – 230 4.0 1 (.75) 2.2 1.0
208/230 1 10.0 15
KBVF-24P 9677 208/230 3 5.2 10 0 – 230 4.0 1 (.75) 2.0 0.9
KBVF-26D* 9496
115 1 22.0 25
0 – 230 5.5 11⁄2 (1.13) 2.9 1.3
208/230 1 14.0 20
*Model KBVF-26D is rated 2 HP (1.5 kW) for most Premium Efficient motors.
Note: All models contain Motor Filter and Quick-Connect Terminals for AC line and motor wiring. The Signal Isolator and Run/Fault Relay is optional
on all models.