It is recommended
that the drive be
used with Inverter Duty
or TENV motors.
Inverter duty and most
totally enclosed non-
ventilated (TENV) motors
can provide full rated
torque over an extended
speed range without
overheating. See Figure 5.
If external fan cooling is
provided, open ventilated
motors can also achieve
an extended speed range
at full rated torque. A box
fan or blower with a mini-
mum of 100 CFM is rec-
ommended. Mount the
fan or blower so the
motor is surrounded by
the airflow. See Figure 6.
20
Maximum Allowed
Motor Speed (%)
10 20
0
040
5030 807060 10090
80
60
40
100
Motor Torque (%)
TEFC and Open Ventilated Motors
and TENV Motors
Inverter Duty
Fan Cooled
FIGURE 5 MAXIMUM ALLOWED MOTOR TORQUE VS. SPEED
Open Ventilated Motor
(100 CFM Min.)
Fan or Blower
Airflow
FIGURE 6 OPEN VENTILATED MOTOR WITH EXTERNAL COOLING
Seitenansicht 20